Specifications - Section 08 34 00
Part 1 - General |
| |
1 . 1 |
Work included Supply only of ; |
| |
|
. 1 |
Bullet Resistant Steel Frames. |
| |
|
. 2 |
Bullet Resistant Steel Doors. |
| |
|
. 3 |
Bullet Resistant Glazing.
|
| |
1 . 2 |
Related Work |
| |
|
. 1 |
Building frames into walls. |
| |
|
. 2 |
Installation of doors and hardware. |
| |
|
. 3 |
Drilling and tapping of doors and frames for surface mounted hardware. |
| |
|
. 4 |
Caulking of joints between frames and other building components. |
| |
|
. 5 |
Finish hardware. |
| |
|
. 6 |
Finish painting. |
| |
|
. 7 |
Wiring and/or conduit for electronic hardware. |
| |
|
. 8 |
Insulation of exterior frame product perimeter members. |
| |
|
. 9 |
Fasteners for frame product in previously placed concrete, masonry or structural steel.
|
| |
1 . 3 |
Requirements of Regulatory Agencies |
| |
|
. 1 |
Product shall be tested in conformance with UL 752, "Standard for Bullet Resisting Equipment".
|
| |
1 . 4 |
Compliance with Ballistic Safety Requirements |
| |
|
. 1 |
As part of the submittal process the manufacturer of the door/frame units shall submit independent test data from a recognized licenced laboratory indicating compliance with the ballistic rating specified (UL Levels 1-8) by the project architect or engineer.
|
| |
1 . 5 |
Warranty |
| |
|
. 1 |
Materials and workmanship shall be warranted by the manufacturer for a period of five (5) years from the date of supply. Warranty shall apply to replacement or retrofit of product only.
|
| |
1 . 6 |
Approved Manufacturers |
| |
|
. 1 |
Ambico Limited
1120 Cummings Avenue
Ottawa, Ontario, Canada,
K1J 7R8
Phone (613) 746-4663
Fax (613) 746-4721
Toll Free Phone (North America): 888 423-2224
Toll Free Fax (North America): 800 465-8561
|
Part 2 - Products |
| |
2 . 1 |
Materials |
| |
|
. 1 |
Steel: Commercial grade, zinc coated steel to ASTM A653. |
| |
|
. 2 |
Primer: Touch-up prime only |
| |
|
. 3 |
Core: Core materials shall be the manufacturer's proprietary bullet resistant standard tested in accordance with UL 752 most current edition. Core shall provide level of protection as specified by the architect. |
| |
|
. 4 |
Glazing: Security glass shall be factory installed. The attack resistance of the glass shall conform to that of the door/frame unit.
|
| |
2 . 2 |
Fabrication |
| |
|
. 1 |
General:
A. : Frames and doors shall be manufactured according to proprietary tests in conformance with UL 752.
B. : Frames and doors shall be blanked, reinforced, drilled and tapped for mortised, templated hardware.
C. : Mortised cutouts shall be protected with steel guard boxes.
D. : Frames and doors shall be reinforced, where required, for surface mounted hardware.
E. : Each door opening shall be prepared for single stud rubber door silencers, three (3) for single door openings, two (2) for double door openings.
F. : Provide factory-applied, touch-up primer at areas where zinc coating has been removed during fabrication.
|
| |
2 . 3 |
Fabrication - Frames, Welded Type |
| |
|
. 1 |
Frame product shall be accurately mitred and securely welded on the inside of the profile. |
| |
|
. 2 |
Welded joints shall be ground to a smooth, uniform finish. |
| |
|
. 3 |
Floor anchors shall be securely attached to the inside of each jamb profile. |
| |
|
. 4 |
Weld in two (2) temporary jamb spreaders per frame to maintain proper alignment during shipment. |
| |
|
. 5 |
Glazing stops shall be 3/16" x 1 3/4" flat bead, accurately fitted, butted at corners and fastened to frame sections with counter-sunk, oval head, sheet metal, tamperproof screws.
|
| |
2 . 4 |
Fabrication - Doors |
| |
|
. 1 |
Doors shall be swing type, flush, with provision for bullet resistant glazing as indicated on schedules. |
| |
|
. 2 |
Longitudinal edges shall be butt seamed. Edge seams shall be visible. |
| |
|
. 3 |
Top and bottom of doors shall be provided with inverted, recessed channels spot welded to door faces.
|
Part 3 - Execution |
| |
3 . 1 |
Site Storage and Protection of Materials |
| |
|
. 1 |
All materials shall be thoroughly inspected upon receipt and all discrepancies, deficiencies and/or damages shall be immediately reported in writing to the supplier. |
| |
|
. 2 |
All materials shall be properly stored on planks or dunnage, out of water and covered to protect them from damage from any cause.
|
| |
3 . 2 |
Installation |
| |
|
. 1 |
Set frames plumb, square, level and at correct elevation. |
| |
|
. 2 |
Secure anchorages and connections to adjacent construction. |
| |
|
. 3 |
Make allowance for deflection to ensure structural loads are not transmitted to frame product. |
| |
|
. 4 |
Protect glazing from site damage. |
| |
|
. 5 |
Install doors and hardware in accordance with hardware templates and manufacturer's instructions. |
| |
|
. 6 |
Adjust operable parts for correct clearances and function.
|