Specifications - Section 08348/08 34 73
Acoustic Steel Door & Frame Assembly
Part 1 - General |
| |
1 . 1 |
Work Included Supply Only of; |
| |
|
. 1 |
Acoustic steel frames. |
| |
|
. 2 |
Acoustic steel doors,swing type. |
| |
|
. 3 |
Door gasketing along perimeter jambs & header. |
| |
|
. 4 |
Door bottom gasketing. |
| |
|
. 5 |
Acoustic glazing.
|
| |
1 . 2 |
Related Work |
| |
|
. 1 |
Building frames into walls. |
| |
|
. 2 |
Installation of doors and hardware. |
| |
|
. 3 |
Drilling and tapping of doors and frames for surface mounted hardware. |
| |
|
. 4 |
Caulking of joints between frames and other building components. |
| |
|
. 5 |
Finish hardware. |
| |
|
. 6 |
Finish painting. |
| |
|
. 7 |
Fasteners for frame product in previously placed concrete, masonry or structural steel.
|
| |
1 . 3 |
Requirements of Regulatory Agencies |
| |
|
. 1 |
Install fire labelled steel door and frame products in accordance with NFPA-80, current edition, except where specified otherwise. |
| |
|
. 2 |
Product shall be tested in conformance with established test procedures for measuring acoustic performance and in particular with ASTM E90-90 and ASTM E413-87.
|
| |
1 . 4 |
Compliance with Required Acoustic Performance |
| |
|
. 1 |
As part of the submittal process the manufacturer of the door/frame units shall submit independent test data from a recognized licenced laboratory indicating compliance with the Sound Transmission Class (STC) specified by the project architect or engineer.
|
| |
1 . 5 |
Warranty |
| |
|
. 1 |
Material and workmanship shall be warranted by manufacturer for a period of five (5) years from the date of supply. Warranty shall apply to replacement or retrofit of product only.
|
| |
1 . 6 |
Approved Manufacturers |
| |
|
. 1 |
Ambico Limited
1120 Cummings Avenue
Ottawa, Ontario, Canada,
K1J 7R8
Phone (613) 746-4663
Fax (613) 746-4721
Toll Free Phone (North America): 888 423-2224
Toll Free Fax (North America): 800 465-8561
|
Part 2 - Products |
| |
2 . 1 |
Materials |
| |
|
. 1 |
Steel: Commercial grade zinc coated steel to ASTM A653 |
| |
|
. 2 |
Acoustic Composite Core: Core material for units shall be manufacturer's proprietary standard, tested as part of a fully operable assembly in accordance with ASTM E90-90 and ASTM E413-87 to provide the Sound Transmission Class (STC) specified by the architect. |
| |
|
. 3 |
Primer: Rust inhibitive touch-up only.
|
| |
2 . 2 |
Fabrication |
| |
|
. 1 |
General:
A. : Frames and doors shall be manufacturer's proprietary standard, tested as part of a fully operable assembly in conformance with ASTM E90-90 and ASTM E413-87 to provide the Sound Transmission Class (STC) specified by the architect.
B. : Frames and doors shall be blanked, reinforced, drilled and tapped for mortised, templated hardware.
C. : Frames and doors shall be reinforced where required for surface mounted hardware.
D. : Frames shall be prepared for and supplied complete with manufacturer's proprietary design of frame gasketing system.
E. : Provide factory-applied, touch-up primer at areas where zinc coating has been removed during fabrication.
|
| |
2 . 3 |
Fabrication - Frames, Welded Type |
| |
|
. 1 |
Frame product shall be accurately mitred and securely welded on the inside of the profile. |
| |
|
. 2 |
Welded joints shall be ground to a smooth, uniform finish. |
| |
|
. 3 |
Floor anchors shall be securely attached to the inside of each jamb profile. |
| |
|
. 4 |
Weld in two (2) temporary jamb spreaders per frame to maintain proper alignment during shipment. |
| |
|
. 5 |
Glazing stops shall be accurately fitted, butted at corners and fastened to frame sections with counter-sunk, oval head, sheet metal, tamperproof screws.
|
| |
2 . 4 |
Fabrication - Doors |
| |
|
. 1 |
Doors shall be swing type, flush, with provision for acoustic glass as indicated on schedules. |
| |
|
. 2 |
Longitudinal edges shall be seamless. Seams shall be welded, filled and ground smooth. |
| |
|
. 3 |
Top and bottom of doors shall be provided with inverted, recessed channels spot welded to door faces, and flush, closed top channels. |
| |
|
. 4 |
Core shall be proprietary acoustic composite core as tested by manufacturer to meet specified STC rating.
|
| |
2 . 5 |
Acoustic Glazing |
| |
|
. 1 |
Acoustic glass shall be factory installed. The acoustic level of the glass shall conform to that of the door/frame unit.
|
Part 3 - Execution |
| |
3 . 1 |
Site Storage and Protection of Materials |
| |
|
. 1 |
All materials shall be thoroughly inspected upon receipt and all discrepancies, deficiencies and/or damages shall be immediately reported in writing to the supplier.
|
| |
3 . 2 |
Installation |
| |
|
. 1 |
Set frames plumb, square, level and at correct elevation in accordance with manufacturer's installation instructions. |
| |
|
. 2 |
Fire labelled frames shall be installed in accordance with NFPA-80, most current edition. |
| |
|
. 3 |
Secure anchorages and connections to adjacent construction. |
| |
|
. 4 |
Make allowance for deflection to ensure structural loads are not transmitted to frame product. |
| |
|
. 5 |
Mask glazing prior to on-site painting. |
| |
|
. 6 |
Install doors and hardware in accordance with hardware templates and manufacturer's instructions. |
| |
|
. 7 |
Adjust operable parts for correct clearances and function.
|